English | Français
Heavy-Duty, Maintenance-Free, Adjustable

Series 7600 WT
Adjustable Weighted Heavy-Duty Backdraft Damper

Series 7600 WT HD Backdraft Damper
  • Weights provide increased load resistance and tighter shut-off.
  • Fully-adjustable weights are mounted outside the air stream. This permits the blade opening to be tailored to achieve the required resistance and optimal performance, based on installation conditions. (Weights are removable.)
  • TAMCO heavy-duty backdraft dampers are constructed with robust components to withstand up to 12” w.g. (3.0 kPa) of static pressure and velocities up to 3500 fpm (17.8 m/s).
  • Blades are designed with a rounded head. This reduces pressure loss.
  • The Series 7600 WT is manufactured with the same dual bearing system used for TAMCO's control dampers, resulting in dependable, consistent, maintenance-free performance.
  • The sturdy, slip-proof linkage system is located in the frame side.
  • Silicone seals are provided as standard to ensure sealing longevity and remain flexible down to -40° F/C.
  • TAMCO Series 7600 WT is available in two install types: Flanged to Duct or Extended Front Flange.
  • The Series 7600 WT can be installed for either Horizontal Airflow and Airflow Up operation.

  • Caution: Never use any lubricants, such as grease or silicone on TAMCO dampers.

Series 7600 WT Adjustable Weighted Heavy-Duty Backdraft Damper:

  • For installations where adjustable blade resistance is required to resist or delay opening.
  • Used to increase resistance to the opening of blades against airflow until a desired static pressure is achieved.
  • Specifically designed for applications requiring a heavy-duty backdraft damper, subjected to elevated velocities and operating pressures.

ET - Elevated Temperature Option:

  • Suitable for high heat environments where temperatures may reach as high as 300°F (149°C),and where UL regulated control dampers are not a requirement.
  • For use in back-up generator stations, where excessive heat may be an issue.
  • For test laboratory applications, wherever high-heat conditions may exist.
  • A practical solution in mildly acidic applications, where Celcon bearings may not withstand environmental conditions.(See Options for more details.)

Recommendation: In applications where the humidity level is unusually elevated, or where there are extremely high levels of dust and dirt particles, TAMCO recommends that the damper linkage and bearing system should be cleaned once a year. This can be done by blowing away dust using compressed air. If needed, a domestic-strength steam cleaner can be used to loosen dirt, which can then be blown out with compressed air, along with any remaining water droplets.

ET - Elevated Temperature Option:

  • Heavy-duty backdraft dampers are designed for operation in temperatures as high as 300°F (149°C).
  • Bronze-oilite bearings replace Celcon and polycarbonate bearings.

Series 7600 WT Submittal and Performance Data

Series 7600 WT Suggested Specifications

TAMCO Heavy-Duty Backdraft Damper Installation Guidelines

Heavy-Duty Backdraft Damper Schedule